Semi–Permeable Capsule Kits
SPC Generation Kit (Flux)
Designed for
Single-cell isolation into SPCs on the Flux system
Includes
Microfluidic chips, oils, SPC generation and release reagents, additional components
Runs
Up to 8 samples with ~200,000 SPCs generated per chip lane
SPC Innovator Kits (Onyx)
Designed for
Single-cell isolation into SPCs on the Onyx microfluidic platform
Includes
Microfluidic chips, oils, SPC generation and release reagents, additional components
Download Catalog
Microfluidic Kits
Droplet Generation Kits
Designed for
Partitioning samples into water-in-oil droplets (one aqueous inlet) using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 6 samples, each capable of at least 2 hours of run-time
Co-Flow Droplet Generation Kits
Designed for
Partitioning samples into water-in-oil droplets (two aqueous inlets) using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 6 samples, each capable of at least 2 hours of run-time
Reagent Addition Kit
Designed for
Reagent addition into water-in-oil droplets using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 3 samples, each capable of at least 2 hours of run-time
Size
Reinjected: 25 - 40 µm;
Post-addition: 30 - 50 µm.
Droplet Merging Kit
Designed for
Pairwise water-in-oil droplet merging using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 3 samples, each capable of at least 2 hours of run-time
Size
Reinjected: 25 - 30 µm; Generated on-chip: 40 - 45 µm;
Post-merging: 40 - 50 µm.
Droplet Selection Kit
Designed for
Fluorescence activated droplet sorting using the Styx microfluidic system
Includes
Microfluidic chips, spacing oil, tubing and additional components
Runs
Up to 5 samples, capable of at least 4 hours of run-time
Download Catalog
Custom Chip Design
To help you accomplish even the most complex microfluidic assay ideas, we offer custom chip prototyping and manufacturing services with a fast turnaround time. All custom client designs are kept strictly confidential.
Typical Project Workflow
MICROFLUIDIC CHIP DESIGN
2-5 days
A custom microfluidic chip is designed according to the client’s needs and
specifications by our highly experienced engineers.
PhotolithograpHy templates
7–10 days
The prepared design is used to make a high-resolution photolithography
mask, which is then patterned on a silicon wafer by photolithography. The
prepared template is inspected and measured to verify the feature quality.
CUSTOM CHIP MANUFACTURING
10–20 days
PDMS elastomer is casted on a photolithography template and the design of
microchannels is imprinted on the polymer’s surface. The PDMS slab is then
bound to a glass slide and the device channels coated to achieve a hydrophobic surface. The quality of each chip is manually inspected prior
to shipping.